{"product_id":"replacement-hydraulic-pump-2542ks","title":"EQ Systems Replacement Hydraulic Pump 2542KS | Multi-Function Systems | Leveling + Slide-Out","description":"\u003cp\u003eReplace the pump in your \u003cstrong\u003emulti-function EQ Systems hydraulic system\u003c\/strong\u003e (one power unit running both leveling jacks and slide-out rooms) with the \u003cstrong\u003eEQ Systems Hydraulic Pump Assembly 2542KS\u003c\/strong\u003e — a uni-directional pump with reversing valve assembly. Available at The RV Surplus.\u003c\/p\u003e\n\n\u003ch3\u003e⭐ Read the Model Number Off Your Existing Pump BEFORE Ordering\u003c\/h3\u003e\n\u003cp\u003eThe pump model number is on the sticker on the pump itself, and it is the same as the SKU here. \u003cstrong\u003eThat number is the only reliable way to order\u003c\/strong\u003e: the same-looking pump can carry a different reservoir, cover, motor and manifold depending on the system it was built for.\u003c\/p\u003e\n\n\u003ch3\u003e⭐ Application: Multi-Function Systems (Leveling + Slide)\u003c\/h3\u003e\n\u003cp\u003eThe 2542KS is used on \u003cstrong\u003emulti-function systems\u003c\/strong\u003e — the systems that run leveling jacks and slide-out rooms from one power unit.\u003c\/p\u003e\n\n\u003ch3\u003e⭐ Matching Parts — Uni-Directional Assembly\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eReservoir: \u003cstrong\u003e2542K\u003c\/strong\u003e\n\u003c\/li\u003e\n  \u003cli\u003eMotor solenoid: \u003ca href=\"\/en-ca\/products\/replacement-solenoid-1444\"\u003e\u003cstrong\u003e1444\u003c\/strong\u003e\u003c\/a\u003e\n\u003c\/li\u003e\n  \u003cli\u003eDirectional valve: \u003ca href=\"\/en-ca\/products\/dv1-directional-valve-1717\"\u003e\u003cstrong\u003eDV1 1717\u003c\/strong\u003e\u003c\/a\u003e\n\u003c\/li\u003e\n  \u003cli\u003eCoil: \u003ca href=\"\/en-ca\/products\/coil-1746\"\u003e\u003cstrong\u003e1746\u003c\/strong\u003e\u003c\/a\u003e\n\u003c\/li\u003e\n  \u003cli\u003eFor the correct motor, check the Motor Replacement Chart or call with the numbers off your pump\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e⭐ Before You Replace a Pump — Check Power First\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eMost pump complaints turn out to be power, not pump.\u003c\/strong\u003e Depending on the pump and motor combination, \u003cstrong\u003eup to 160 amperes at a minimum of 10.5 VDC\u003c\/strong\u003e can be required to run the motor, through \u003cstrong\u003eminimum 4 gauge power and ground cables\u003c\/strong\u003e. Some lithium batteries cannot deliver that running amperage.\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCheck the ground to the pump stud for tightness and corrosion\u003c\/li\u003e\n  \u003cli\u003eCheck the positive cable to the motor solenoid for tightness and corrosion\u003c\/li\u003e\n  \u003cli\u003eIf the motor runs but nothing moves, look at the \u003cstrong\u003efluid level and trapped air\u003c\/strong\u003e before condemning the pump\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eSetting Up a New Pump\u003c\/h3\u003e\n\u003cp\u003eMount the pump where the fill and breather cap can be reached for filling. Fill with \u003cstrong\u003eDexron III ATF\u003c\/strong\u003e to about one inch below the top of the reservoir with the jacks fully retracted (level rises as the jacks retract). \u003cstrong\u003eRemove the flush shipping plug and fit the vented breather cap before running the system\u003c\/strong\u003e, or the jacks will operate erratically. Manual override is standard on every EQ Systems pump.\u003c\/p\u003e\n\n\u003ch3\u003eDocuments\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/eqsystems.us\/cdn\/shop\/files\/Reservoir-Replacement-Chart-Feb-2023-TM-1.pdf\" target=\"_blank\"\u003eReservoir Replacement Chart (PDF)\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/eqsystems.us\/cdn\/shop\/files\/Cover-Replacement-Chart-11.7.22-TM.pdf\" target=\"_blank\"\u003eCover Replacement Chart (PDF)\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/eqsystems.us\/cdn\/shop\/files\/Motor-Replacement-Chart-2021-TM.pdf\" target=\"_blank\"\u003eMotor Replacement Chart (PDF)\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/eqsystems.us\/cdn\/shop\/files\/TS-Motor-Solenoid-for-EQ-Hydraulic-Pumps-TM.pdf\" target=\"_blank\"\u003eMotor and Solenoid Troubleshooting for EQ Hydraulic Pumps (PDF)\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/eqsystems.us\/cdn\/shop\/files\/Required-Maintenance-Items-Hydraulic-Systems-EQ-TM.pdf\" target=\"_blank\"\u003eRequired Maintenance Items for EQ Hydraulic Jacks \u0026amp; Slide Systems (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOther Replacement Pumps\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003ca href=\"\/en-ca\/products\/replacement-hydraulic-pump-3218ks\"\u003e\u003cstrong\u003ePump 3218KS\u003c\/strong\u003e\u003c\/a\u003e — also for multi-function systems (3.7 MTE)\u003c\/li\u003e\n  \u003cli\u003e\n\u003ca href=\"\/en-ca\/products\/replacement-hydraulic-pump-3195ks\"\u003e\u003cstrong\u003ePump 3195KS\u003c\/strong\u003e\u003c\/a\u003e — also for multi-function systems\u003c\/li\u003e\n  \u003cli\u003e\n\u003ca href=\"\/en-ca\/products\/replacement-hydraulic-pump-3170ks\"\u003e\u003cstrong\u003ePump 3170KS\u003c\/strong\u003e\u003c\/a\u003e — for AJ\/AM single\/dual systems\u003c\/li\u003e\n  \u003cli\u003e\n\u003ca href=\"\/en-ca\/products\/replacement-hydraulic-pump-3201ks\"\u003e\u003cstrong\u003ePump 3201KS\u003c\/strong\u003e\u003c\/a\u003e — for AJ\/AM single\/dual systems\u003c\/li\u003e\n  \u003cli\u003e\n\u003ca href=\"\/en-ca\/products\/replacement-hydraulic-pump-3200ks\"\u003e\u003cstrong\u003ePump 3200KS\u003c\/strong\u003e\u003c\/a\u003e — for TJ single leg\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e90-Day Warranty\u003c\/h3\u003e\n\u003cp\u003eBacked by EQ Systems' \u003cstrong\u003e90-day replacement part warranty\u003c\/strong\u003e. Check documentation for full terms.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eBrand: EQ Systems\u003c\/li\u003e\n  \u003cli\u003eModel: Hydraulic Pump Assembly 2542KS\u003c\/li\u003e\n  \u003cli\u003eSKU: 2542KS\u003c\/li\u003e\n  \u003cli\u003eType: Uni-directional pump with reversing valve assembly\u003c\/li\u003e\n  \u003cli\u003eApplication: Multi-function systems (leveling + slide-out)\u003c\/li\u003e\n  \u003cli\u003eMatching Reservoir: 2542K\u003c\/li\u003e\n  \u003cli\u003eMotor Solenoid: 1444\u003c\/li\u003e\n  \u003cli\u003eDirectional Valve: DV1 1717 with coil 1746\u003c\/li\u003e\n  \u003cli\u003eManual Override: Standard\u003c\/li\u003e\n  \u003cli\u003eFluid: Dexron III ATF\u003c\/li\u003e\n  \u003cli\u003ePower Requirement: Up to 160A at 10.5 VDC minimum\u003c\/li\u003e\n  \u003cli\u003eCable Requirement: 4 gauge minimum power and ground\u003c\/li\u003e\n  \u003cli\u003eWarranty: 90-day replacement part warranty\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"EQ Systems","offers":[{"title":"Default Title","offer_id":58467184673071,"sku":"2542ks","price":1211.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0729\/7663\/0063\/files\/2542ks.jpg?v=1789394603","url":"https:\/\/thervsurplus.com\/en-ca\/products\/replacement-hydraulic-pump-2542ks","provider":"The RV Surplus","version":"1.0","type":"link"}