Coleman | Mach Control Box | 9530A751 | Heat Pump
Coleman | Mach Control Box | 9530A751 | Heat Pump
Couldn't load pickup availability
Add heat pump and heat strip control to your Coleman Mach RV system with the Coleman Mach 9530A751 Heat-Ready Heat Pump Control Box. This 12V DC control box is engineered specifically for Coleman Mach HP2 Heat Pumps and Mach 8 air conditioners with heat strip — operating compressor, high fan, low fan, and heat relays via low-voltage thermostat control to deliver both cooling and heat pump heating from a single wall thermostat.
Wired for Full Heat Pump Function
Unlike basic cool-only control boxes, the 9530A751 is wired for full heat pump operation:
- Compressor relay — drives the heat pump compressor for both cooling and heating modes
- High fan relay — high-speed airflow operation
- Low fan relay — low-speed airflow operation
- Heat relay — controls heat strip when installed
The result: full year-round climate control through a single wall thermostat — cooling in summer, heat pump heating in moderate cold weather, and electric heat strip backup when temperatures drop below heat pump efficiency thresholds.
Electric Heat Strip Ready
The 9530A751 supports an optional electric backup heat strip (sold separately) for supplemental heating when heat pump efficiency drops in colder temperatures. Compatible heat strip part numbers:
- Coleman Mach 4700 Series: Heat strip #47233-4551 (sold separately)
- Coleman Mach 48000 / 49000 Series: Heat strip #9233-4551 (sold separately)
⚠️ Compatibility — HP2 Heat Pumps and Mach 8 Only
This control box is engineered specifically for:
- Coleman Mach HP2 Heat Pumps
- Coleman Mach 8 air conditioners with heat strip
It is NOT compatible with cool-only AC units or non-Coleman Mach brands. Verify your AC type before ordering — using the wrong control box for your AC type will result in incompatible operation.
⚠️ One Control Box Required Per Rooftop Unit
Each rooftop heat pump or air conditioner requires its own dedicated control box. If your RV has multiple units, you need one 9530A751 per heat pump or Mach 8 unit.
⚠️ Not for Zone Control Installations
The 9530A751 is not a zone control box. For zone-controlled heat pump installations (multi-zone systems with separate temperature control areas), the 9630A751 zone control heat pump box is required instead — same heat pump function, but engineered for zone control wiring.
⚠️ External 12 VDC Required for Thermostat
The 9530A751 control box does not supply 12 VDC power to the wall thermostat. This voltage must be provided externally by the RV's 12V system. Ensure your installation provides a proper 12 VDC feed to the thermostat circuit before completing wiring. Consult the installation instructions for correct wiring diagram and terminal designations.
Required Wall Thermostat — Sold Separately
The 9530A751 requires a compatible wall thermostat to operate. The matching Coleman Mach wall thermostat is the Coleman 9420A382 Digital Wall Thermostat — single-stage heat/cool control with digital LCD readout and high/low fan speeds. The 9420A382 replaces the older 8530A3451 thermostat (no longer in production) as the current required thermostat for this control box.
Other Coleman Mach Control Boxes — Pick by AC Type
The 9530A751 is the heat pump control box for HP2 and Mach 8 systems. If your installation uses a different AC type, the matching control box is different:
- Coleman 8330-752 Cool-Only Control Package — for cool-only AC installations with no heating capability
- Coleman 9330C755 Heat-Ready Control Box — for cool-only AC with electric heat strip support
Low Voltage Terminal Functions
The 9530A751 uses the following low-voltage terminal designations on the control box strip:
- B (Blue): Completes –12 VDC circuit for all relays
- Y (Yellow): Energizes compressor relay coil
- GH (Green): Energizes high fan relay coil
- GL (Gray): Energizes low fan relay coil
- W (White): Energizes heat relay coil
- FREEZE: Evaporator freeze sensor connection
Refer to the installation instructions wiring diagram for complete thermostat wire routing and high-voltage connection details.
Evaporator Freeze Sensor Included
The 9530A751 includes an evaporator freeze sensor (shipped separately in an envelope for field installation at the evaporator coil). The freeze sensor monitors evaporator temperature to prevent ice buildup during extended low-load cooling operation.
What's Included
- (1) 9530A751 Control Box Assembly
- (1) Evaporator Freeze Sensor (in envelope for field installation)
- Installation Hardware
- Wiring Diagram / Instructions
Sold Separately
- Wall Thermostat: Coleman Mach 9420A382 (replaces discontinued 8530A3451)
- Heat Strip: 47233-4551 (4700 Series) or 9233-4551 (48000/49000 Series)
Key Features
- Heat pump and heat-ready control box for Coleman Mach HP2 and Mach 8 systems
- Wired for full heat pump function — compressor, high fan, low fan, and heat relays
- Electric heat strip ready — supports optional backup heat strip (sold separately)
- 12 VDC operation on standard RV low-voltage power
- Evaporator freeze sensor included for field installation
- Requires Coleman Mach 9420A382 wall thermostat (sold separately — replaces discontinued 8530A3451)
- One control box required per rooftop unit
- Not a zone control box — for zone heat pump applications, use 9630A751
- External 12 VDC feed required for the wall thermostat
- Compact dimensions: 14-1/8" L × 3-1/8" W × 2-1/8" H
- Backed by a 1-year limited manufacturer warranty
Specifications
- Brand: Coleman Mach (Airxcel)
- Part Number: 9530A751
- Type: Heat Pump / Heat-Ready Control Box
- Compatible Units: Coleman Mach HP2 Heat Pumps; Mach 8 AC with Heat Strip
- NOT Compatible With: Cool-only AC units; non-Coleman Mach brands
- Voltage: 12 VDC
- Required Wall Thermostat: Coleman Mach 9420A382 (sold separately) — replaces discontinued 8530A3451
- Compatible Heat Strip (4700 Series): 47233-4551 (sold separately)
- Compatible Heat Strip (48000/49000 Series): 9233-4551 (sold separately)
- Zone Control: No (use 9630A751 for zone heat pump applications)
- Per-Unit Requirement: One control box required per rooftop heat pump / AC unit
- Thermostat 12 VDC Supply: Externally supplied by RV (not from this control box)
- Dimensions: 14-1/8" L × 3-1/8" W × 2-1/8" H
- Includes: Control box, evaporator freeze sensor, mounting hardware, wiring diagram/instructions
- Warranty: 1-year limited manufacturer warranty