Dometic
Dometic FreshJet 5 Heat Pump RV AC | White | Penguin II | FJX5557EHP
Dometic FreshJet 5 Heat Pump RV AC | White | Penguin II | FJX5557EHP
Couldn't load pickup availability
Replace your Penguin II with the next-generation Dometic FreshJet 5 with Heat Pump — White (Part #FJX5557EHPWHCS / SKU 9620017216). Direct low-profile replacement engineered to match the existing Penguin II 10.5" installed height and mounting footprint — no roof modifications needed. Approximately 15,000 BTU cooling AND integrated heat pump for efficient electric heating. Pre-installed electronic control board, built-in hard start, and R32 refrigerant.
Prefer Black Instead?
Also available in black as the Dometic FreshJet 5 with Heat Pump — Black (FJX5557EHPBKCS). Same construction and features — black finish for modern exterior color schemes.
⚠️ CRITICAL — Thermostat Requirements (Electronic Heat Pump Units)
Before ordering, read this section carefully. The FreshJet 5 Electronic Heat Pump has specific thermostat compatibility requirements — the wrong setup can prevent operation entirely. Contact us before ordering if you have any doubt about your configuration.
Scenario 1 — Multi-Zone with another Penguin II using the 10-button CCC2 thermostat:
- You MAY HAVE TO switch the thermostat to the new Connect Essential Thermostat (9610007991)
- This is the only standard way to pair the FJ5 with Heat Pump and a Penguin II together simultaneously
⚠️ Want to Keep Your CCC2 Thermostat? Alternative Installation Available
The standard FJ5 installation is not compatible with CCC2 (Comfort Control Center 2) thermostats. If you're replacing a Penguin II and want to continue using your existing CCC2 thermostat, there's an alternative installation approach that reuses the original Penguin II control board with the new FJ5 HP unit:
- 📹 Video walkthrough: Alternative FJ5 HP installation with CCC2 thermostat retention — shows how to keep the old Penguin II board so the CCC2 can continue to be used.
- 📄 Forest River memo sheet: Step-by-step board-swap reference sheet — reference alongside the video.
⚠️ Not a simple process — this alternative install requires board swapping and rewiring. It can be done, but it's not recommended for first-time DIY installers. If you'd rather use the FJ5's native controls or upgrade to a compatible Dometic thermostat, the standard installation is much more straightforward.
Scenario 2 — Multi-Zone with another Penguin II using a DIFFERENT thermostat (not 10-button CCC2):
- Please reach out to us before ordering — you may or may not be forced to switch BOTH ACs to make the system work
Scenario 3 — Single Zone install (only this AC on the system):
- The FJ5 Heat Pump AC typically will not work without a newer Connect Essential thermostat
- You can use the Connect Essential Thermostat v1 (4471011652)
⭐ Furnace + Heat Pump — Managed by One Thermostat
Important capability: the Connect Essential thermostat manages both this heat pump AC AND a furnace simultaneously. The system automatically prioritizes heat pump operation until the outdoor ambient temperature reaches near freezing, then switches over to furnace operation for efficient cold-weather heating. No need for a separate furnace-only thermostat.
⚠️ This Guidance Applies to Electronic Heat Pump Units ONLY
The above thermostat requirements apply specifically to the electronic control board FJ5 Heat Pump units (the FJX5557EHP series — white and black). Requirements are meaningfully different for the mechanical heat pump variants (FJX5557MHP series).
⭐ Direct Penguin II Replacement — Same Height and Footprint
The FreshJet 5 is engineered as a drop-in replacement for the Dometic Penguin II:
- Same 10.5" installed height as Penguin II
- Same mounting footprint
- No roof modifications required
⭐ Integrated Heat Pump for Electric Heating
- Reversible refrigerant cycle for efficient electric heat
- Cooling AND heating from one rooftop unit
- Reduced propane/furnace dependency in mild weather
⭐ Pre-Installed Electronic Control Board
Critical difference from the FreshJet 3 mechanical models: this unit comes with a pre-installed Multi-Zone FreshJet electronic control board.
⚠️ RJ-11 to RJ-45 Adapter Required for Most Penguin II Replacements
Where the existing installation uses RJ-11 wiring (from the legacy Penguin II era) that needs to tie into the new RJ-45-based FreshJet 5 system, the Dometic RJ-11 to RJ-45 Adapter Harness Kit (9610008210) is required. Typical requirement: 2 kits per FreshJet 5 unit (one at the unit, one at the thermostat).
⭐ Built-In Hard Start
Built-in hard start improves startup performance and reduces the chance of tripping breakers when multiple appliances start simultaneously. Meaningful for RVs on 30-amp service or generator power.
15,000 BTU High-Efficiency Cooling
- Approximately 15,000 BTU cooling capacity
- High-Efficiency model — strong cooling performance with lower power consumption
- R32 refrigerant — enhanced efficiency and reduced environmental impact
- Reinforced steel base for long-term durability
⭐ Up to 9dB Quieter (Non-Ducted Setups)
Upgraded motor and blower system: up to 9dB quieter operation in non-ducted setups.
⚠️ R32 Refrigerant Compatibility
- R410A equipment may be replaced with R32-designed components
- R410A equipment CANNOT be used in R32-designed systems
- R32 refrigerant CANNOT be used in R410A-based air conditioners
Ducted OR Non-Ducted Installation
⭐ Pre-Installed Roof Compression Gasket
Comes with a pre-installed roof compression gasket on the base of the unit — no additional sealant or roof gasket required.
⭐ SHIPS FREE via Freight to the 48 States
Free freight shipping to the 48 contiguous states. Most orders arrive within a week.
⚠️ Freight Shipping Note
Large-format freight item — inspect thoroughly upon delivery and note any damage on the delivery receipt before signing.
Cross-Reference Part Numbers
- Manufacturer Part: FJX5557EHPWHCS
- SKU: 9620017216
White Finish
⚠️ Professional Installation Required
Installation involves rooftop mounting, weather sealing, 120V AC electrical wiring, control network wiring (potentially with RJ-11 to RJ-45 adapters), and thermostat integration. Installation should be performed by a qualified RV service technician.
2-Year Manufacturer Warranty
Genuine Dometic OEM
Key Features
- Genuine Dometic OEM FreshJet 5 with Heat Pump rooftop AC
- Part number: FJX5557EHPWHCS (SKU 9620017216)
- Direct low-profile replacement for Dometic Penguin II — same 10.5" height and mounting footprint
- Approximately 15,000 BTU cooling — High-Efficiency model
- Integrated heat pump for efficient electric heating
- R32 refrigerant
- Pre-installed Multi-Zone FreshJet electronic control board
- ⚠️ May requires Connect Essential thermostat for single-zone installs (v1 4471011652 or CMC 9610007991)
- ⚠️ Multi-zone with Penguin II on 10-button CCC2: MUST switch to Connect Essential 9610007991 or alternate path
- ⚠️ Multi-zone with P2 on different thermostat: contact us before ordering
- ⚠️ Furnace + heat pump: requires a separate furnace-only external thermostat (Dometic has no combined solution)
- Built-in hard start — improved startup reliability
- Up to 9dB quieter in non-ducted setups
- Reinforced steel base for durability
- Ducted OR non-ducted installation
- Pre-installed roof compression gasket — no additional sealant needed
- Black color sibling available: FJX5557EHPBKCS
- RJ-11 to RJ-45 adapter typically required for Penguin II wiring replacement (SKU 9610008210 — usually 2 per unit)
- White finish
-
SHIPS FREE via freight to 48 states
- Backed by 2-year manufacturer warranty
Specifications
- Brand: Dometic
- Series: FreshJet 5
- Part Number: FJX5557EHPWHCS
- SKU: 9620017216
- Type: RV Rooftop Air Conditioner with Integrated Heat Pump (Low-Profile)
- Cooling Capacity: Approximately 15,000 BTU (High Efficiency)
- Heat Pump: Yes (integrated electric heating)
- Refrigerant: R32
- Hard Start: Built-in
- Configuration: Ducted OR Non-Ducted
- Installed Height: 10.5" (matches Penguin II)
- Mounting Footprint: Matches Penguin II
- Direct Replaces: Dometic Penguin II
- Noise Reduction: Up to 9dB quieter in non-ducted setups
- Control Board: Pre-installed Multi-Zone FreshJet electronic control board
- Compatible Thermostats: Dometic Connect Essential v1 (4471011652), Dometic Connect Essential RV-C and CMC (9610007991)
- ⭐ Furnace + heat pump: managed by one Connect Essential thermostat with automatic switchover based on outdoor temp
- Base Construction: Reinforced steel
- Roof Compression Gasket: Pre-installed
- Required Companion (for Penguin II replacements with existing RJ-11 wiring): RJ-11 to RJ-45 Adapter Kit (SKU 9610008210) — typically 2 per unit
- Color: White
- Black Color Sibling: Dometic FJX5557EHPBKCS
- Shipping: Ships FREE via freight to 48 states (typical arrival within a week)
- Warranty: 2-year manufacturer warranty

Questions & Answers
2 questions answered about this part
-
Can I Keep My 4-Button Thermostat With a New RV AC?
No. The 4-button Comfort Control Center is obsolete, and no recent or current-generation air conditioner can communicate with it. You'll need to move to a CCC2, a Dometic Connect Essential, or a Micro-Air EasyTouch.
See the full answer -
What Replaces One of Two Dometic Blizzard NXT Heat Pumps?
Staying with Dometic on one thermostat means a FreshJet 5 with Heat Pump plus the Connect Essential 9610007991 thermostat, which lets the remaining Blizzard's CCC2 board keep talking to the new unit. You'll also need three RJ-11 to RJ-45 harnesses — no new wire behind the wall.
See the full answer
Have a question about this part or whether it fits your RV?
Ask us — we answer every one